01 Is aluminum wiring actually dangerous? +
Not automatically — and anyone telling you to panic is selling something. Aluminum branch wiring went into Canadian homes roughly between 1965 and 1975, and where it was installed properly and terminated with compatible devices, it can be perfectly safe. The risk lives at the connections: aluminum expands, contracts and oxidises more than copper, so terminations can work loose over decades and heat up. That is what gets inspected, and that is what gets fixed.
02 My insurer is asking about my wiring. What do they actually want? +
It varies by insurer, so get their requirement in writing first — it saves everyone guessing. Most commonly they want an inspection by a licensed electrical contractor confirming what the wiring is and that the terminations are done with compatible, approved devices. Some ask for remediation before they will write the policy; a few will not cover knob-and-tube at all. We will tell you exactly what you have, in writing. What we will not do is promise what your insurer will accept — nobody honestly can.
03 Do I have to rewire the whole house? +
Usually not, if it is aluminum. The common approach is to correct the terminations throughout — compatible, approved devices and connectors — rather than opening up every wall. A full rewire is the definitive fix and sometimes it is genuinely the right call, but it is rarely the only option, and we will say so. Knob-and-tube is a different story: it is ungrounded, its insulation is long past its service life, and it cannot be brought up to modern standard, so replacement is the honest answer there.
04 How do I know which one I have? +
Age is the first clue. Knob-and-tube is roughly pre-1950 — you can often spot the white ceramic knobs and tubes on the joists in an unfinished basement or attic. Aluminum is roughly 1965 to 1975, and the cable jacket is usually marked ALUMINUM or ALUM. Plenty of Sudbury homes have had work done since they were built, so what is in the panel is not always what is in the walls. If you are not sure, we will look.
05 Is knob-and-tube under attic insulation a problem? +
Yes — and it is one of the more common things worth catching. Knob-and-tube was designed to shed its heat into open air, so burying it in thermal insulation traps that heat. It is a recognised hazard and generally not permitted. If an attic was insulated over live knob-and-tube at some point, that is worth dealing with rather than leaving.
06 Do you handle the permits and inspection side? +
Yes. Work is done to the Ontario Electrical Safety Code and filed with the ESA (Electrical Safety Authority) where a permit is required — our ESA permits guide explains how that process works. You get the paperwork; we deal with the process.